United SCP, static control on a higher level

< Back  | Live Chat | Telephone 719 676 3928 | Search

ElectraGuard NC

Application Instructions

 

ElectraGuard NC Application Instructions

PRODUCT DESCRIPTION
Gray, Beige and Clear Epoxy Floor Coating
Product PN: EG-NC followed by color (clear, beige or gray)

APPLICATION: New concrete floors should be allowed to cure a minimum of thirty days. Application to floors colder than 60 degrees F. is not recommended. Floor surfaces must be free of any release agents, curing compounds, salts or efflorescence before coating. The use of a DiamaBrush or diamond grinder is helpful in removing and preparing the concrete. Remove the dust and residues by auto scrubbing or damp mopping using a diluted solution of ElectraClean and clean water. Allow the floor to dry. Always pretest the coating for adhesion prior to full application. Concrete Repair: Please click here

If the floor has been previously coated, a small area should be cleaned, roughed up by screen disking with an 80 Grit screen and the product should be tested for adhesion, lifting and compatibility using one of our bond strength test kits. Any areas of the existing coating which display poor adhesion should be removed. DiamaBrush if needed and rinse thoroughly with clean cool water. Allow the floor to dry.

Catalyzed ElectraGuard NC should be used within six hours of mixing, therefore, prepare only the quantity necessary for immediate use. Add the premeasured catalyst to the epoxy base. Stir gently using a rotary paint stirrer until the catalyst has been thoroughly mixed in to the base. Allow the catalyzed ElectraGuard NC to stand for 5 minutes.

Apply the catalyzed ElectraGuard NC with a 3/8 nap roller in thin, uniform coats. The initial coat will cover approximately 300 -500 square feet per gallon. Allow the initial coat to dry for 5-7 hours, then apply a second coat. Second coat coverage is approximately 400 to 600 SF per gallon. Optimal esthetics are obtained with a 3rd coat.

NOTE: Finished floors may be opened to light traffic, under normal curing conditions, after 12 hours. Complete curing with maximum durability and chemical resistance will take 5-7 days.

NOTE: As applied the pigmented versions of ElectraGuard NC has a nice semi-gloss appearance. The Clear version is a high gloss product. For a diamond like shine top coat with 2 to 3 coats of ElectraSheen Sapphire II and high speed burnish.

Color Medium Gray, Beige and Clear
Solids: 32 + 1%
pH 4.0 - 5.0
Weight Per Gallon: 8.5
Hardness: 30 (Sward)
Viscosity: 400 - 800 CPS
Solvents Water-glycol
Flash Point: greater than 200 degrees Fahrenheit
Freeze/Thaw Stability: Do Not Freeze
Dry Time Dry to touch: 5-7 hours
Open for traffic: 10-12 hours
Water Resistance: Not recommended for standing water
Chemical Resistance
Slip Resistance: (ASTM F 609) >.5 SCOF
Typical Average Coverage: 350 - 450 square feet per gallon per coat.
Odor: Moderate (Glycol Ether, Alcohol)
VOC <450 grams/liter, Health 1, Flammability 0, Reactivity 0. Personal Protection B

SDS SHEET for Gray     SDS SHEET for Clear 


w3c compliant

*