ElectraFlow HD-303Mission Critical ESD Ionizer with Air FiltrationSpecifications and InstallationMethod of operation and uses: The HD 303 is an extreme service fully portable stand-alone mission critical bench top or desktop ionizer. The HD-303 emits a powerful yet balanced ionic output that overwhelms static laden insulative items or conductive items that are insulated from a ground source.Uses include:
Mechanical Properties
Decay Test Results / Other Pertinent Data
Installation: The HD-303 features an attached heavy duty adjustable metal stand with a non-marring, non-slip base. The ionizer may be simply placed on the work bench or table top or bolted to the underside of a work bench shelf. Electrical Requirements: The HD-303 requires 110VAC /60Hz (standard) or 220VAC / 50Hz (optional) power. The instrument is equipped with a 3 prong grounded US male plug (standard). Do not modify the plug or use an ungrounded 3 prong receptacle. If an extension cord is required use heavy gauge fully grounded cords of no longer than 6 feet.
Operating Procedure: Activate the ionizing blower by turning fan speed knob clockwise. The ionization indicator will illuminate and indicate the presence of balanced ionized air. Airflow speed can easily be adjusted utilizing the fan speed knob. The time required to neutralize electrostatic potential is dependent on distance of ionizer to work surface and the speed of fan. When used in electronic assembly the ionized air stream should cover as much of the working area as possible. The constant flow of ionized air prevents items from developing an electrostatic potential.
Note: This item is NOT recommended for use in explosive or inflammable environments.
Routine Maintenance Overview: Inspect the emitter points on occasion. They should look clean and sharp. To clean ion emitter pins press and turn point cleaner knob (located in middle of air outlet) clockwise approximately one turn and reverse to lock into start position. Clean air inlet and outlets as needed with a soft brush or vacuum. Replace filter as needed. Periodically test ion output as indicated by your internal ESD program or ANSI/ESD S 20.20-2014, TR53, Air Ionizer Compliance Verification (discharge time and offset voltage). Offset voltages of >+/- 35 volts or decay rates that exceed user defined times may indicate the need for a replacement of emitters. Normal emitter life is 5 to 10 plus years, replacement emitters are easy to install and available from United SCP.
Contact United Static Control Products! Tame the Static Beast Before it Takes another Byte! © 1996 - 2021 All rights Reserved w3c compliant |